BQTWJ - YELLOW L.F. GLOSS LACQUER, 910KYLW

  • MSDS: BQTWJ
  • Manufacturer: KINDT COLLINS CO
  • Product Name: YELLOW L.F. GLOSS LACQUER, 910KYLW
  • National Stock Number: 8010-00N037403
Product Identification

Product ID:YELLOW L.F. GLOSS LACQUER, 910KYLW
MSDS Date:01/14/1992
FSC:8010
NIIN:00N037403
MSDS Number: BQTWJ

Responsible Party
KINDT-COLLINS CO
12651 ELMWOOD AVE
CLEVELAND, OH 44111
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 216-252-4122

Cage: EO495

Contractor
KINDT-COLLINS COMPANY
CLEVELAND, OH 44111 US

Telephone: (216) 252-4122

Cage: EO495

Ingredients

5.1

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 17.88%

OSHA PEL 100 PPM;150 STEL

ACGIH TLV: 100 PPM;150 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ACETIC ACID, ISOBUTYL ESTER; (ISOBUTYL ACETATE) (SARA

CAS: 110-19-0

RTECS: AI4025000

Fraction By Weight: 27.45%

OSHA PEL 150 PPM

ACGIH TLV: 150 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


1.3

CAS: 28553-12-0

Fraction By Weight: 4.32%


ACETIC ACID, 2-METHOXY-1-METHYLETHYL ESTER; (PM ACETATE).

CAS: 108-65-6

RTECS: AI8895000

Fraction By Weight: 6.86%

OSHA PEL N/K

ACGIH TLV: N/K


33

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 6.11%

OSHA PEL 400 PPM;500 STEL

ACGIH TLV: 400 PPM;500 STEL


BE EXPLOSION-PROOF. AVOID ANY DIRECT INHALATION OF

RTECS: 9999999ZZ


TRAIN AND EDUCATE EMPLOYEES IN THE SAFE

RTECS: 9999999ZZ


TO PM ACETATE. APPROPRIATE MEASURES SHOULD

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SEVERE EYE IRRIT. AVOID INHALING
SOLVENT VAPORS. EXCESSIVE INHALATION MAY CAUSE HEADACHES,
DIZZINESS, AND/OR NAUSEA. EXCESSIVE SOLVENT VAPOR LEVELS OVER LONG
PERIODS OF TIME IN THE AIR WHERE SOLVENT P AINTS ARE APPLIED MAY
LEAD TO NERVE DAMAGE, DEPENDING UPON CONC LEVELS OF VAPORS &
EXPOSURE DURATIONS. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: NOTICE: REPORTS HAVE ASSOCIATED
REPEATED AND PROLONGED OCCUPATIONAL OVEREXPOSURE TO SOLVENTS WITH
PERMANENT BRAIN AND NERVOUS SYSTEM DAMAGE. INTENTIONAL MISUSE BY
DELIBERATELY CONCENTRATING AND INHALING THE CONTENTS MAY BE
HARMFUL OR FATAL. SKIN ABSORP MAY POTENTIALLY CONTRIBUTE TO OVERALL
EXPOSURE (ING 8)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES:FLUSH THORO W/WATER FOR @ LST 15 MIN. LIFTING UPPER &
LOWER LIDS OCCASIONALLY. GET IMMED MEDICAL ATTN. SKIN:WASH EXPOSED
AREAS WITH SOAP & WATER. REMOVE CONTAMINATED CLOTHING IF IRRITATION
OCCURS , GET MEDICAL ATTN. INGEST: DO NOT INDUCE VOMIT, KEEP VICTIM
WARM & QUIET. ASPIR OF MATL INTO LUNGS DUE TO VOMIT CAN CAUSE CHEM
PNEUMONITITS WHICH CAN BE FATAL. GET IMMED MED ATTN. (SUPP DATA)

Fire Fighting

Flash Point Method:TCC
Flash Point:53.0F,11.7C
Lower Limits:1.0%
Extinguishing Media:FOAM, CARBON DIOXIDE (CO*2) DRY CHEM/WATER FOG
SPRAY. SOLID HOSE STREAMS TEND TO SCATTER LIQ & SPREAD FIRE. (SUPP
DATA)
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . STREAMS OF WATER ARE NOT ORDINARILY
EFFECTIVE.
Unusual Fire/Explosion Hazard:FLAMMABLE VAPORS MAY FORM EXPLOSIVE
MIXTURES WITH AIR.

Accidental Release

Spill Release Procedures:IF SPILL IS LRG & HAZARD TO PUBLIC SAFETY,
CALL CHEMTREC AT 1-800-424-9300. COLLECT IN A RETAINING AREA OR
CONTAINER. THEN TRANSFER TO A CLOSED CONTAINER. AVOID EXPOSURE TO
HEAT, SPARKS, FIRE OR OPEN FLAME. AVOID HOT METAL SURFACES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS, FIRE AND
OPEN FLAME. USE ONLY WITH ADEQUATE VENTILATION. AVOID PROLONGED OR
REPEATED CONTACT WITH SKIN.
Other Precautions:CLEAN ALL CNTNR OPENINGS & KEEP TIGHTLY SEALED. STORE
UPRIGHT & SECURE IN A COOL, DRY APPRVD AREA (40-80F). AVOID INHAL
OF DRY OVERSPRAY. EMPTIED CNTNRS MAY RETAIN HAZ RESIDUE & EXPLO
VAPS. KEEP AWAY FROM HEAT, SPARKS & FLAMES. (SUPP DATA)

Exposure Controls

Respiratory Protection:UNLESS PRIOR WORKER MONITORING SPECIFICALLY FOR
SOLVENT CONC LEVELS HAS INDICATED THAT SAFE EXPOSURE LEVELS EXIST
IN THE OPERATION, A NIOSH/MSHA APPROVED SCBA IS REQUIRED.
Ventilation:ADEQ VENT IS NEC WHEN SPRAYING OR MIXING & EXHST W/PROPER
AIRFLOW IS ALWAYS RECOMMENDED. ALL ELEC EQUIP MUST (ING 6)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEM WORK GOG W/FULL LENGTH FSHLD
Other Protective Equipment:MAY ADHERE TO SKIN. LONG SLEEVES, HATS
RECOMMENDED. PROT CREAMS MAY HELP BUT ARE NOT AS PROT AS GLOVES,
ETC. (ING 7)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXTING MEDIA: WATER FOAMS, WATER SPRAYS OR FOG NOZZLES COOL THE BURNING
SURFACE AND EXCLUDE AIR. FIRST AID PROC: INHAL: MOVE VICTIM AWAY
FROM SOURCE OF EXPOSURE & INTO FRESH AIR. IF SYMPTOMS OF EXPOSU RE
DEVELOP, GET MED ATTN. OTHER PREC: DO NOT CUT, PUNCTURE OR WELD ON
OR NEAR EMPTIED CONTAINERS.

Chemical Properties

Boiling Pt:B.P. Text:>180F,>82C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.05
Evaporation Rate & Reference:1.56 X N-BUTYL ACETATE
Appearance and Odor:YELLOW HEAVY LIQUID
Percent Volatiles by Volume:70.3

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:AVOID HEAT, SPARKS, FIRE OR OPEN FLAMES.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY YIELD CARBON
MONOXIDE.

Disposal

Waste Disposal Methods:MATERIAL SHOULD BE CONSIDERED A HAZARDOUS WASTE
AND SUBJECT TO HAZARDOUS WASTE REGULATIONS FOR DISPOSAL. DISPOSAL
MUST BE IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.